Saudi Building Code guides

Plain-language guides answering common compliance questions, cited to code sections.

What does Saudi Building Code (SBC) compliance mean?

Saudi Building Code compliance means a building's design and drawings meet the code's requirements (e.g. SBC 201 for buildings and SBC 801 for fire protection) before the project is approved by the competent authority.

What is the minimum room area in the Saudi Building Code?

In SBC 201 (clause 1208.3) every dwelling unit needs at least one room with a net floor area of not less than 11.2 m2, and every other habitable room needs not less than 6.5 m2. Kitchens are not required to have a minimum floor area.

SBC 201 §1208.3

What are the egress path and door width requirements in the building code?

In SBC 201 a door needs a clear opening at least 800 mm wide (clause 1010.1.1) and a stairway is at least 1100 mm wide (clause 1011.2). On top of that, capacity is worked out from the occupant load: 7.6 mm per occupant for stairways (clause 1005.3.1) and 5.08 mm per occupant for other egress components (clause 1005.3.2).

SBC 201 §1005.3

What does the fire-protection code SBC 801 require?

SBC 801 covers fire-protection requirements: element fire-resistance ratings, means of egress, and alarm and suppression systems — reducing fire risk and ensuring safe evacuation.

SBC 801

What are the Saudi Building Code requirements for doors?

In SBC 201 (clause 1010.1.1) a door in the means of egress needs a clear opening at least 800 mm wide and 2000 mm high. A door serving a room with an occupant load of 50 or more, or a Group H occupancy, swings in the direction of egress travel (clause 1010.1.2.1).

SBC 201 §1010.1.1

What are the stair riser height and tread depth in the Saudi Building Code?

In SBC 201 (clause 1011.5.2) a stair riser is at most 175 mm and at least 100 mm high, and a tread is at least 275 mm deep. Inside dwellings (Group R-3 and within dwelling units in Group R-2) the riser may be up to 200 mm and the tread at least 250 mm.

SBC 201 §1011.5.2

What is the minimum stair width in the Saudi Building Code?

The minimum stairway width in SBC 201 is 1100 mm (clause 1011.2), or 900 mm where the stairway serves an occupant load of less than 50. Headroom above the stair must be at least 2100 mm (clause 1011.3).

SBC 201 §1011.2

What is the maximum dead-end corridor length in the Saudi Building Code?

A dead-end corridor may not be longer than 6 m where more than one exit or exit access doorway is required (SBC 201, clause 1020.5). The limit rises to 15 m in Groups B, E, F, I-1, M, R-1, R-2, S and U where the building is sprinklered throughout.

SBC 201 §1020.5

How many exits does a story need in the Saudi Building Code?

Each story needs at least 2 exits for up to 500 occupants, 3 for 501 to 1,000, and 4 for more than 1,000 (SBC 201, clause 1006.3.3 and Table 1006.3.3). A single exit is allowed only in the cases of clause 1006.3.4.

SBC 201 §1006.3.3

When does a room or space need two exits in the Saudi Building Code?

A room or space needs two exits or exit access doorways when its occupant load or its common path of egress travel distance exceeds Table 1006.2.1 (SBC 201, clause 1006.2.1). For example: more than 49 occupants in Groups A, B, E, F, M and U, more than 29 in S, more than 20 in R-2.

SBC 201 §1006.2.1

What is the minimum ceiling height in the Saudi Building Code?

The minimum ceiling height in SBC 201 (clause 1208.2) is 2250 mm above the finished floor in occupiable spaces, habitable spaces and corridors, and 2100 mm in bathrooms, toilet rooms, kitchens, storage rooms and laundry rooms.

SBC 201 §1208.2

What window area does the Saudi Building Code require for natural light and ventilation?

For natural light, the net glazed area is at least 8 percent of the floor area of the room served (SBC 201, clause 1204.2). For natural ventilation, the openable area to the outdoors is at least 4 percent of the floor area being ventilated (clause 1202.5.1).

SBC 201 §1204.2

When does the Saudi Building Code require an automatic sprinkler system?

Section 903.2 of SBC 201 sets the trigger by occupancy group. For example: Group A-2 where the fire area exceeds 465 m2 or the occupant load is 100 or more; Groups A-1, A-3 and A-4 above 1115 m2 or at 300 occupants or more; and every building with a Group R or Group I fire area.

SBC 201 §903.2

How wide must a fire apparatus access road be under SBC 801?

A fire apparatus access road needs an unobstructed width of at least 6 m, not counting shoulders, and an unobstructed vertical clearance of at least 4 m (SBC 801, clause 503.2.1). The road must reach to within 45 m of all portions of the exterior walls of the first story (clause 503.1.1).

SBC 801 §503.2.1

How many accessible parking spaces does the Saudi Building Code require?

Where parking is provided, Table 1106.2 of SBC 201 (clause 1106.2) sets the number of accessible spaces: 1 for 1 to 25 spaces, 2 for 26 to 50, 4 for 76 to 100, and 2% of the total for 501 to 1,000 spaces.

SBC 201 §1106.2