Window area for natural light and ventilation — SBC 201
For natural light, the net glazed area is at least 8 percent of the floor area of the room served (SBC 201, clause 1204.2). For natural ventilation, the openable area to the outdoors is at least 4 percent of the floor area being ventilated (clause 1202.5.1).
| Requirement | Minimum | Clause |
|---|---|---|
| Net glazed area for natural light | 8% of the room's floor area | 1204.2 |
| Openable area for natural ventilation | 4% of the floor area being ventilated | 1202.5.1 |
| Artificial light (the alternative to natural light) | an average of 107 lux at 750 mm above the floor | 1204.3 |
Example: a room with a 20 m2 floor needs a net glazed area of at least 1.6 m2 (20 × 8%) and an openable area of at least 0.8 m2 (20 × 4%).
Clause 1204.1 requires every space intended for human occupancy to have natural light through exterior glazed openings under clause 1204.2, or artificial light under clause 1204.3. Exterior glazed openings open directly onto a public way, or onto a yard or court under Section 1205.
Natural ventilation is through windows, doors, louvers or other openings to the outdoors, with the opening mechanism within ready reach of the occupants (clause 1202.5). Clause 1202.1 makes mechanical ventilation under SBC 501 the alternative, and requires it for ambulatory care facilities and Group I-2.
Read clause 1204.2 in the code reader
General educational content (ref: SBC 201 §1204.2) — pending licensed-engineer review; not an official certification. Always rely on the official code text.