Saudi Code for Structural Concrete Reinforced with Glass Fiber-Reinforced Polymer Bars (SBC 311)
Edition 2024 · 173 pages · 30 chapters · 1318 clauses
Contents
- Chapter 1 General
- 1.1 Scope of the Code (SBC 311)
- 1.2 General
- 1.3 Purpose of This Code
- 1.4 Applicability
- 1.5 Interpretation
- 1.6 Building official
- 1.7 Licensed design professional
- 1.8 Construction Documents and Design Records
- 1.9 Testing and Inspection
- 1.10 Acceptance of Alternative Systems for Design or Construction or Alternative Construction Materials
- Chapter 2 Notation and Terminology
- Chapter 3 Referenced Standards
- Chapter 4 Structural System Requirements
- 4.1 Scope
- 4.2 Materials
- 4.3 Design Loads
- 4.4 Structural System and Load Paths
- 4.5 Structural Analysis
- 4.6 Strength
- 4.7 Serviceability
- 4.8 Durability
- 4.9 Sustainability
- 4.10 Structural Integrity
- 4.11 Fire resistance and service temperature increase
- 4.12 Requirements for Certain Special Types of Construction
- 4.13 Construction and Inspection
- 4.14 Strength Evaluation of Existing Structures
- Chapter 5 Loads
- Chapter 6 Structural Analysis
- Chapter 7 One-way slabs
- Chapter 8 Two-Way Slabs
- Chapter 9 Beams
- Chapter 10 Columns
- Chapter 11 Walls
- 11.1 Scope
- 11.2 General
- 11.3 Design Limits
- 11.4 Required strength
- 11.5 Design strength
- 11.6 Limiting Values of Glass Fiber-Reinforced Polymer Bar Reinforcement
- 11.7 Reinforcement Details with Glass Fiber-Reinforced Polymer Bars
- 11.8 Alternative Method for Out-of-Plane Analysis of Slender Walls – Out of Scope
- Chapter 12 Diaphragms – Not Addressed
- Chapter 13 Foundations
- Chapter 14 Plain concrete – not applicable
- Chapter 15 Beam-column joints and slabs
- Chapter 16 Connections Between Structural Members
- Chapter 17 Anchoring to Concrete – Not Addressed
- Chapter 18 Earthquake-Resistant Structures – Not Addressed
- Chapter 19 Concrete Design and Durability Requirements
- Chapter 20 Properties of glass fiber-reinforced polymer bar reinforcement, durability, and embedments
- Chapter 21 Strength reduction factors
- Chapter 22 Sectional Strength
- Chapter 23 Strut-and-Tie Models – Not Addressed
- Chapter 24 Serviceability Requirements
- 24.1 Scope
- 24.2 Deflection due to gravity loads at service level
- 24.3 Distribution of Flexural Reinforcement in One-Way Slabs and Beams
- 24.4 Glass fiber-reinforced polymer bar reinforcement to resist shrinkage and temperature
- 24.5 Permissible stresses in prestressed concrete flexural members – out of scope
- 24.6 Allowable Tensile Stresses in Glass Fiber-Reinforced Polymer Bars
- Chapter 25 Reinforcement Details with Glass Fiber-Reinforced Polymer Bars
- 25.1 Scope
- 25.2 Minimum Spacing of Glass Fiber-Reinforced Polymer Bars
- 25.3 Standard hooks, crossties, minimum inside diameter of flexure of bars
- 25.4 Development Length of Glass Fiber-Reinforced Polymer Bars
- 25.5 Splices of Reinforcement
- 25.6 Bundled reinforcement – out of scope
- 25.7 Transverse Reinforcement with Glass Fiber-Reinforced Polymer Bars
- 25.8 Post-tensioning anchorages and couplers – out of scope
- 25.9 Anchorage zones for post-tensioning tendons – out of scope
- Chapter 26 Construction Documents and Inspection
- 26.1 Scope
- 26.2 Design Criteria
- 26.3 Member Information
- 26.4 Concrete Materials and Mixing Requirements
- 26.5 Concrete Production and Construction
- 26.6 Reinforcement Materials with Glass Fiber-Reinforced Polymer Bars and Construction Requirements
- 26.7 Anchoring to Concrete – Out of Scope
- 26.8 Embedments in Concrete
- 26.9 Additional Requirements for Precast Concrete
- 26.10 Additional Requirements for Prestressed Concrete – Out of Scope
- 26.11 Formwork
- 26.12 Evaluation and Acceptance of Hardened Concrete
- 26.13 Inspection/Examination
- Chapter 27 Strength evaluation of existing concrete structures
- Appendix A Fire resistance
- Appendix B Residential Walls and Slabs-on-Ground
- Appendix C Alternative to the Requirements of Chapter 18 – Earthquake-Resistant Structures
- C18.1 Scope
- C18.2 General Provisions
- C18.3
- C18.4
- C18.5
- C18.6
- C18.7
- C18.8 Intentionally left blank
- C18.9 Intentionally left blank
- C18.10 Intentionally left blank
- C18.11 Intentionally left blank
- C18.12 Intentionally left blank
- C18.13 Foundations
- C18.14 Members Not Designated as Part of the Seismic Force-Resisting System
- C18.15 Hybrid Reinforcement