15.4 Structural Connection Details
SBC 311 · Edition 2024 · p. 102
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 15.4.1 Beam-column joints or joints of columns with slabs shall satisfy the requirements for transverse reinforcement with glass fiber-reinforced polymer bars given in (Section 15.4.2).
- 15.4.2 The area of glass fiber-reinforced polymer transverse reinforcement legs in each principal direction of beam-column joints and slabs shall not be less than the values calculated in accordance with the requirements of Section 15.4.2.
- 15.4.3 Where glass fiber-reinforced polymer bars of the beam or column are spliced or terminated at the joint, closed transverse reinforcement shall be provided in the joint in accordance with the requirements of (Section 10.7.6).
- 15.4.4 Longitudinal polymer bars terminated in connections shall be anchored in accordance with the requirements of Section 25.4.