- 15.2.1 Beam-column joints and column-slab joints shall satisfy the requirements of Section 15.3 for the transfer of column axial forces through the floor system.
- 15.2.2 Where gravity loads, wind, earthquake, or other lateral forces cause transfer of moments at beam-column joints or slab-column joints, the shear forces resulting from the transfer of moments shall be considered in the design of the structural joint.
- 15.2.3 Beam-column joints and slabs that transfer moments to columns shall satisfy the detailed requirements of Section 15.4.
- 15.2.4 Beam-column joints shall be considered confined if the joint is laterally supported on four sides by beams of approximately the same depth.
- 15.2.5 Slab-column joints shall be considered restrained if the joint is laterally supported on four sides by the slab.