24.3 Distribution of Flexural Reinforcement in One-Way Slabs and Beams
SBC 311 · Edition 2024 · p. 130
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 24.3.1 Glass fiber-reinforced polymer bars shall be distributed to control cracking due to flexure in the tension zones of slabs and beams reinforced for flexure in one direction only.
- 24.3.2 The spacing of reinforcing bars closest to the tension face shall not exceed the limits given in Section 24.3.2.
- 24.3.3 Where a single reinforcing bar is located near the end of the tension face, the width of the end of the extreme tensioned face shall not exceed the values of spacing between reinforcing bars calculated in accordance with the requirements of (Section 24.3.2).
- 24.3.4
- 24.3.5 For one-way slabs and beams subject to fatigue or designed to be watertight, the spacing of flexural reinforcement bars shall be selected based on investigations and precautions specific to those conditions, and shall not exceed the limits given in (Section 24.3.2).