9.8.3.8 Termination of Reinforcement
SBC 312 · Edition 2024 · p. 141
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 9.8.3.8.1 At simple supports, at least one-third of the maximum positive moment reinforcement shall extend along the bottom of the beam into the support a sufficient distance, except that in precast beams such reinforcement shall extend at least to the center of the bearing length.
- 9.8.3.8.2 At other supports, at least one-fifth of the maximum positive moment reinforcement shall extend along the bottom of the beam into the support for a sufficient distance; where the beam is part of the primary lateral load resisting system, (f_y) shall be developed at the face of support.
- 9.8.3.8.3 At simple supports and points of inflection, (d_b) for positive moment reinforcement shall be limited such that (l_d) for that reinforcement satisfies the requirements of (Section 9.8.3.8.3).
- 9.8.3.8.4 At least one-third of the negative moment reinforcement shall have a development length extending beyond the point of inflection not less than (d, 12d_b,and l_n/16).