7.8.1 General
SBC 312 · Edition 2024 · p. 117
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 7.8.1.1
- 7.8.1.2 The nominal shear strength of two-way members without shear reinforcement shall be calculated in accordance with the requirements of Section 7.8.1.2.
- 7.8.1.3 The nominal shear strength of two-way members with shear reinforcement shall be calculated in accordance with the requirements of Section 7.8.1.3.
- 7.8.1.4 Two-way shear strength shall be provided by a section with a depth (d) and an assumed critical perimeter (bo) as defined in (Section 7.8.4).
- 7.8.1.5 Vc for two-way shear shall be calculated in accordance with the requirements of Section 7.8.5. For two-way members with shear reinforcement, Vc shall not exceed the limits given in Section 7.8.7.1.
- 7.8.1.6 When calculating (Vc), the value of (λ) shall be calculated in accordance with the requirements of (Section 3.4.4).
- 7.8.1.7 For two-way members reinforced with single- or multiple-leg stirrups, (Vs) shall be calculated in accordance with the requirements of (Section 7.8.8).
- 7.8.1.8 For two-way members reinforced with headed shear studs, (Vs) shall be calculated in accordance with the requirements of (Section 7.8.9).