7.7.1 General
SBC 312 · Edition 2024 · p. 113
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 7.7.1.1 The nominal strength for one-way shear at a section (Vn) shall be calculated in accordance with the requirements of Section 7.7.1.1.
- 7.7.1.2 The dimensions of the cross section shall be limited to satisfying the requirements of Section 7.7.1.2.
- 7.7.1.3 For non-prestressed members, the value of (Vc) shall be calculated in accordance with the requirements of Sections (7.7.5, 7.7.6, or 7.7.7).
- 7.7.1.4 For pretensioned members, the value of (Vc, Vci, Vcw) shall be calculated in accordance with the requirements of (Sections 7.7.8 or 7.7.9).
- 7.7.1.5 For calculating the values of (Vc, Vci, Vcw), the value of (λ) shall be in accordance with the requirements of (Section 3.4.4).
- 7.7.1.6 The value of (Vs) shall be calculated in accordance with the requirements of (Section 7.7.10).
- 7.7.1.7 The effect of any openings in members shall be considered when calculating the nominal shear strength (Vn).
- 7.7.1.8 The effects of axial tension due to creep and shrinkage in restrained members shall be considered in calculating the nominal shear strength provided by concrete (Vc).
- 7.7.1.9 The effect of inclined flexural compression in variable-depth members shall be considered when calculating the nominal shear strength provided by concrete (Vc).