7.6.2 Maximum axial compression strength
SBC 312 · Edition 2024 · p. 112
The nominal axial compressive strength (P_n) shall not exceed the limit (P_n,max) in accordance with the requirements of Section 7.6.2.
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 7.6.2.1 The nominal axial strength (P_o) of nonprestressed members, composite members of steel and concrete, and prestressed members shall be calculated in accordance with the requirements of (Sections 7.6.2.2 and 7.6.2.3).
- 7.6.2.2 The nominal axial strength (P_o) of nonprestressed members and composite members of steel and concrete shall be calculated in accordance with the requirements of (Section 7.6.2.2).
- 7.6.2.3 The nominal axial strength (P_o) of prestressed members shall be calculated in accordance with the requirements of Section 7.6.2.3.
- 7.6.2.4 The transverse reinforcement for lateral support of longitudinal reinforcement in compression members shall satisfy the requirements of Section 11.8.6.2 and Section 25.7.2, SBC 304.
- 7.6.2.5 The spiral reinforcement for lateral support of longitudinal reinforcement in compression members shall satisfy the requirements of Sections 11.8.6.3 and Section 25.7.3, SBC 304.