7.3.4 For structures that rely on members in (a), (b), or (c) to resist earthquake effects, the value of (ϕ) for shear shall be modified in accordance with the requirements of (Sections 7.3.4.1 through 7.3.4.3):
SBC 312 · Edition 2024 · p. 109
(a) Special moment frames. (b) Special structural walls. (c) Intermediate precast structural walls in structures assigned to seismic design categories (D, E, or F).
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 7.3.4.1
- 7.3.4.2 For diaphragms, the value of (ϕ) for shear shall not exceed the least value of (ϕ) for shear used for the vertical components of the primary seismic-force-resisting system.
- 7.3.4.3 For joints of columns with beams and for diagonally reinforced coupling beams, the value of (ϕ) for shear shall be 0.85.