6.4.6 Seismic Force-Resisting System
SBC 312 · Edition 2024 · p. 101
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 6.4.6.1 Each structure shall be assigned to a seismic design category in accordance with the requirements of SBC 301.
- 6.4.6.2 The structural systems designated as part of the seismic-force-resisting system shall be limited to those systems specified by SBC 301.
- 6.4.6.3 The structural systems assigned to seismic design category (A) shall satisfy the applicable requirements of (SBC 312). Structures assigned to seismic design category (A) are not required to be designed in accordance with the requirements of ( Chapter 4(B).
- 6.4.6.4 Structural systems assigned to seismic design category (B, C, D, E, or F) shall comply with the requirements of (Chapter 4(B)) in addition to the applicable requirements of (SBC 312).
- 6.4.6.5 Structural members that are assumed not to be part of the seismic-force-resisting system are permitted in accordance with the requirements of (Sections 6.4.6.5.1 and 6.4.6.5.2).
- 6.4.6.6 The effects of nonstructural elements shall be calculated as specified in (Section 18.2.2.1, SBC 304), and the consequences of damage to nonstructural elements shall be considered.