5.6.1 It is permitted to calculate (M_u and V_u) due to gravity loads after continuity is achieved in accordance with the requirements of (Section 5.6.1), for continuous beams, one-way solid slabs and one-way ribbed slabs that satisfy the following:

SBC 312 · Edition 2024 · p. 94

(a) Members are prismatic. (b) Loads are uniformly distributed. (c) The live load is less than or equal to three times the dead load (L ≤ 3D). (d) There are at least two spans. (e) The longer of two adjacent…