4B9.3.2 Beams
SBC 312 · Edition 2024 · p. 74
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 4B9.3.2.1
- 4B9.3.2.2 The positive moment strength at the face of the joint shall be not less than one-third of the negative moment strength generated at that face. Furthermore, neither the negative moment strength nor the positive moment strength at any section along the span shall be less than one-fifth of the maximum moment strength generated at that face.
- 4B9.3.2.3 The value of (ϕVn) shall be determined in accordance with the requirements of (Section 4B9.3.2.3).
- 4B9.3.2.4 At both ends of the beam, hoops shall be provided over an appropriate length in accordance with the requirements of (Section 4B9.3.2.4). The first hoop shall be located not more than 50 mm from the face of the supporting member. The spacing of hoops shall comply with the requirements of (Section 4B9.3.2.4).
- 4B9.3.2.5 The spacing of transverse reinforcement along the span of the beam shall be determined in accordance with the requirements of Section 4B9.3.2.5.
- 4B9.3.2.6 In beams in which the factored axial compression strength exceeds (Agf'c/10), the transverse reinforcement required in (Section 4B9.3.2.5) shall conform to the requirements of ( Sections 7A7.2.2 and either 7A7.2.3 (or 7A7.2.4, SBC 1101.