4.3.5 Structural Integrity
SBC 312 · Edition 2024 · p. 56
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 4.3.5.1 All structures shall be provided with a continuous load path, and they shall have a lateral-force-resisting system with adequate strength to resist the specified forces.
- 4.3.5.2 The effects of the forces specified in (Section 4.3.5) on the structure and its components shall be taken as a notional load, and shall be combined with other load effects in accordance with the load combinations given in (Section 5.4).
- 4.3.5.3 Structures designed in accordance with the requirements of (SBC 312) for seismic design categories (B or C) shall be considered to comply with the requirements of (Section 4.3.5).