14.4.3 Design strength
SBC 312 · Edition 2024 · p. 189
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 14.4.3.1
- 14.4.3.2 The value of (Ø) shall be determined in accordance with the requirements of (Section 7.2).
- 14.4.3.3 The moment strength and axial strength of connections shall be calculated in accordance with the requirements of Section 7.6.
- 14.4.3.4
- 14.4.3.5 At the contact surface between the supported member and the foundation, Vn shall be calculated in accordance with the shear friction provisions of Section 7.11 or by other appropriate means.
- 14.4.3.6 At the base of a precast column, pedestal, or wall, anchor bolts and anchors for mechanical connections shall be designed in accordance with the requirements of (Chapter 13). Forces developed during erection shall also be considered.
- 14.4.3.7 At the base of a column, pedestal, or wall, mechanical connections shall be designed to reach their design strength before anchorage failure or failure of the surrounding concrete occurs.