14.3.3 Design strength
SBC 312 · Edition 2024 · p. 187
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 14.3.3.1 The design strength of connections of precast members shall not be less than the required strength for each applicable load combination.
- 14.3.3.2 The value of (Φ) shall be determined in accordance with the requirements of Section 7.2.
- 14.3.3.3
- 14.3.3.4 It is permitted to calculate shear forces (Vn) in accordance with the shear friction requirements given in (Section 7.11), where shear is the principal resultant of the imposed loading and its transfer occurs across a known plane.