13.5 Loads and Load Factors
SBC 312 · Edition 2024 · p. 170
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 13.5.1 With some notable exceptions, such as bearing pads, the design methods given in (Chapter 13) are based on strength design relationships.
- 13.5.2 In addition to gravity loads, wind, and seismic loads, the forces resulting from restraint of volume changes shall be considered, in addition to those required for the purpose of compatibility of deformations.
- 13.5.3
- 13.5.4 Connections are usually designed at the strength-level loads determined by the structural analysis of the structure.
- 13.5.5 Connections shall be designed based on load combinations in accordance with the requirements of Section 4.5.