13.10.6 Strength of concrete in tension
SBC 312 · Edition 2024 · p. 173
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 13.10.6.1 The design tensile strength governed by concrete failure shall be the minimum of the three modes given in (Section 13.10.6.1).
- 13.10.6.2 The nominal concrete breakout strength in tension shall be calculated in accordance with the requirements of Section 13.18.2.
- 13.10.6.3 The nominal concrete pullout strength of an anchor in tension shall be calculated in accordance with the requirements of Section 13.18.3.
- 13.10.6.4 The nominal side-face blowout strength of concrete for a headed anchor in tension shall be calculated in accordance with the requirements of Section 13.18.3.