9.7.7 Structural Integrity Reinforcement in Cast-in-Place Beams
SBC 311 · Edition 2024 · p. 78
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 9.7.7.1 Structural integrity reinforcement for beams located along the perimeter of the structure shall satisfy the requirements of Section 9.7.7.1.
- 9.7.7.2 For beams other than perimeter beams, structural integrity reinforcement shall satisfy the requirements of (Section 9.7.7.2).
- 9.7.7.3 Structural integrity longitudinal bars shall pass within the region enclosed by the longitudinal bars of the columns.
- 9.7.7.4 Longitudinal reinforcement for structural integrity shall be anchored at discontinuous supports to develop (f_fu) at the faces of the supports.
- 9.7.7.5 Where splicing of continuous reinforcement for structural integrity is required, the splices shall conform to the following requirements:
- 9.7.7.6 Connections shall be either mechanical connections conforming to the requirements of Section 25.5.7 or Class (B) tension lap splices conforming to the requirements of Section 25.5.2.