9.7.3 Flexural Reinforcement Using Glass Fiber-Reinforced Polymer Bars
SBC 311 · Edition 2024 · p. 75
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 9.7.3.1 The calculated tension or compression force in the reinforcement at each section of the slab shall be developed on each side of that section.
- 9.7.3.2 The critical locations for placing reinforcing bars are the points of maximum stress and the points along the span where the need for tension reinforcement to resist flexural strength diminishes.
- 9.7.3.3 Reinforcing bars shall extend beyond the point at which their role in providing flexural strength and the stiffness necessary to satisfy deflection requirements ceases, for a distance equal to (d) or (12d_b), whichever is greater, except at supports of simply supported spans and at free ends of cantilevers.
- 9.7.3.4 For continuing tension reinforcement bars, the bars shall extend a distance not less than the development length (l_d) beyond the point at which flexural strength is no longer required.
- 9.7.3.5 Reinforcing bars resisting flexure in tension shall not be cut off in tension zones unless one of the conditions given in (Section 9.7.3.5) is satisfied.
- 9.7.3.6 Adequate anchorage shall be provided for tension reinforcement where reinforcement stress is not directly proportional to moment, or where tension reinforcement is not parallel to the compression face.
- 9.7.3.7 Intentionally left blank.
- 9.7.3.8 Bending of glass fiber-reinforced polymer bars