9.7.2 Spacing of Glass Fiber-Reinforced Polymer Bars
SBC 311 · Edition 2024 · p. 74
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 9.7.2.1 The minimum permitted spacing between reinforcing bars (s) shall be determined in accordance with the requirements of (Section 25.2).
- 9.7.2.2 The spacing of longitudinal reinforcement bars closest to the tension face shall not exceed the spacing (s) given in (Section 24.3).
- 9.7.2.3 For beams with a depth exceeding 450 mm, longitudinal bars shall be added, uniformly distributed along both side faces of the beam for a distance h/2 from the tension face, in accordance with the requirements of Section 9.7.2.3. The spacing of these bars shall not exceed the limits given in Section 24.3.2.