9.6.3 Minimum Shear Reinforcement with Glass Fiber-Reinforced Polymer Bars
SBC 311 · Edition 2024 · p. 73
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 9.6.3.1 A minimum area of shear reinforcement (Afv,min) shall be provided in all regions where (Vu ≥ Ø2.5kcr√f/c bwd), except for the cases given in (Section 9.6.3.1).
- 9.6.3.2 Intentionally left blank.
- 9.6.3.3
- 9.6.3.4 If shear reinforcement is required and the effect of torsion is permitted to be neglected in accordance with the requirements of (Section 9.5.4.1), the minimum transverse reinforcement (Afv,min) shall be the greater of the values given in (Section 9.6.3.4).