8.4.2.2 Factored Moments Resisted by Columns
SBC 311 · Edition 2024 · p. 63
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 8.4.2.2.1 If gravity loads, wind, earthquake, or other loads cause a transfer of moments between the slab and column, the portion of the moment (Msc) resisted by the column at the joint shall be transferred by flexure in accordance with the requirements of (Sections 8.4.2.2.2 and 8.4.2.2.3).
- 8.4.2.2.2 The fraction of the factored slab moment resisted by the column (γfMsc) shall be assumed to be transferred by flexure, where the value of (γf) shall be calculated in accordance with the requirements of (Section 8.4.2.2.2).
- 8.4.2.2.3 The effective slab width (bslab) resisting (γfMsc) shall be the width of the column or capital plus the distance on each side in accordance with the requirements of (Section 8.4.2.2.3).
- 8.4.2.2.4 Intentionally left blank.
- 8.4.2.2.5 Reinforcement shall be concentrated over the column by reducing the spacing between bars or by adding reinforcement to resist the moment over the effective slab width determined in accordance with the requirements of Section 8.4.2.2.2 and 8.4.2.2.3.
- 8.4.2.2.6 It shall be assumed that the fraction of the moment (Msc) not calculated to be resisted by flexure may be resisted by eccentricity of shear in accordance with the requirements of (Section 8.4.4.2).