7.7.7 Structural Integrity Reinforcement in Cast-in-Place One-Way Slabs Using Glass Fiber Reinforced Polymer
SBC 311 · Edition 2024 · p. 59
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 7.7.7.1 At least one-quarter of the maximum longitudinal tension reinforcement shall be continuous for the purpose of structural integrity.
- 7.7.7.2 Longitudinal reinforcement for structural integrity shall be anchored at discontinuous supports to develop the value of (f_fu) at the face of support.
- 7.7.7.3 Where splices are required in continuous reinforcement for structural integrity, the splices shall be made near supports. The connections shall be either mechanical connections conforming to the requirements of Section 25.5.7 or Class (B) tension lap splices conforming to the requirements of Section 25.5.2.