7.7.3 Flexural Reinforcement Using Glass Fiber-Reinforced Polymer Bars
SBC 311 · Edition 2024 · p. 57
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 7.7.3.1 The calculated tension or compression force in the reinforcement at each section of the slab shall be obtained on each side of that section.
- 7.7.3.2 The critical locations for placing reinforcing bars are the points of maximum stress and the points along the span where the need for tension reinforcement to resist flexural strength diminishes.
- 7.7.3.3 Reinforcing bars shall extend beyond the point at which the contribution of flexural strength ceases, and the stiffness necessary to satisfy the deflection requirements shall be provided, for a distance equal to (d) or (12d_b), whichever is greater, except at supports of simply supported spans and at free ends of cantilevers.
- 7.7.3.4 For continuing tension reinforcement bars, these bars shall extend a distance not less than the development length (l_d) beyond the point at which the contribution of flexural strength ceases.
- 7.7.3.5 Reinforcing bars resisting tension in flexure shall not be sheared off in tension zones unless one of the conditions given in (Section 7.7.3.5) is satisfied.
- 7.7.3.6 Adequate anchorage shall be provided for tension reinforcement where the reinforcement stress is not directly proportional to the moment, or where the tension reinforcement is not parallel to the compression face.
- 7.7.3.7 Intentionally left blank.
- 7.7.3.8 Termination of Glass Fiber-Reinforced Polymer Bars