26.9.2 Compliance requirements:

SBC 311 · Edition 2024 · p. 151

(a) Members shall be marked to indicate their location and orientation in the structure and the date of manufacture. (b) Identification marks on members shall correspond to the erection drawings. (c) Details of lifting devices, embedments, and related reinforcement required…

These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.

Read the full clause
SBC 311 26.9.2: Compliance requirements: | Emtithal