25.7.2 Glass Fiber Reinforced Polymer (GFRP) ties
SBC 311 · Edition 2024 · p. 138
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 25.7.2.1 Column ties consist of a closed loop with spacing conforming to the requirements of Section 25.7.2.1.
- 25.7.2.2 The diameter of column ties shall not be less than 10 mm.
- 25.7.2.3 Column ties shall be arranged in a straight line to meet the requirements of Section 25.7.2.3.
- 25.7.2.4 Circular column ties are permitted where longitudinal bars are located around the perimeter of a circle. Circular ties shall be either continuously closed ties or shall be anchored in accordance with the requirements of Section 25.7.2.4.1.
- 25.7.2.5 Column ties used for torsional strength shall be perpendicular to the member axis and shall conform to the requirements of (Section 25.7.1.6).