13.2.7 Critical Sections for Shallow Foundations and Pile Caps
SBC 311 · Edition 2024 · p. 95
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 13.2.7.1 Where the maximum moment (Mu) at the bearing region of a member is calculated, it is permitted to be calculated at the critical section defined in (Section 13.2.7.1).
- 13.2.7.2 The location of the critical section for factored shear in accordance with the requirements of (Sections 7.4.3 and 8.4.3) for one-way shear or in accordance with the requirements of (Section 8.4.4.1) for two-way shear shall be measured from the location of the critical section for moment (Mu) specified in (Section 13.2.7.1).
- 13.2.7.3 Circular or polygonal columns and pedestals are permitted to be treated as square members having the same area when determining critical sections for moments and shear forces.