5.4.4.2 Compression Chord Members
SBC 309 · Edition 2024 · p. 55
The chord member subjected to compression shall be evaluated for axial load only using Chapter 5, SBC 308, for bending in accordance with the requirements of Section 6.1, SBC 308, and for combined axial load and bending in accordance with…
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 5.4.4.2.1 For determination of axial strength, the effective length (KL) shall be determined by rational engineering analysis, by testing, or by the design assumptions specified in Section 5.4.4.2.1.
- 5.4.4.2.2 For determining flexural strength, the effective length (KL) shall be determined by rational engineering analysis, testing, or the design assumptions specified in Section 5.4.4.2.1.
- 5.4.4.2.3 When a C-shape compression chord member is subjected to a concentrated load at a point, the interaction of axial compression, bending and web crippling shall be determined in accordance with the requirements of (Section 5.4.4.2.3).