6.1.2 Design Basis
SBC 307 · Edition 2024 · p. 55
The requirements of this section apply to braced frames consisting of concentrically connected members. Eccentricities less than the beam depth are permitted if they are taken into account in the design of the member by determining the eccentric moments using…
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.