10.6.2.5 Nondestructive Testing for Repair of the Reduced Beam Section
SBC 307 · Edition 2024 · p. 103
Magnetic particle testing (MT) shall be performed on any weld and the adjacent area in the cut surface of a reduced beam section (RBS) that has been repaired by welding, or on the base metal in the cut surface of…