27.3.5 Wind Load Cases for Design Wind Loads
SBC 301 · Edition 2024 · p. 183
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 27.3.5.1 The main wind force resisting system of buildings of all heights, whose wind loads have been determined under the provisions of Chapter 27, shall be designed for the wind load cases defined in Section 27.3.5.1.
- 27.3.5.2 The eccentricity (e) for rigid buildings shall be measured from the geometric center of the building face and shall be considered for each principal axis (ex, ey).
- 27.3.5.3 The eccentricity for flexible buildings shall be determined and shall be considered for each principal axis (ex, ey) in accordance with the requirements of (Section 27.3.5.3).
- 27.3.5.4 The sign of the eccentricity e shall be positive or negative, whichever causes the more severe load effect.