12.2.1 Selection and Limits
SBC 301 · Edition 2024 · p. 69
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 12.2.1.1
- 12.2.1.2 The structural systems used shall be in accordance with the structural system limitations and the limits on structural height, hn, contained in (Section 12.2.1.2).
- 12.2.1.3 The appropriate response modification coefficient, R, overstrength factor, Ω0, and deflection amplification factor, Cd, indicated in (Table 12-1) shall be used in determining the base shear, element design forces, and design story drift.
- 12.2.1.4 Each seismic force-resisting system shall be designed and detailed in accordance with the specific requirements for the system as set forth in the applicable reference document listed in Table 12-1 and the additional requirements set forth in Chapter 14.
- 12.2.1.5 Nothing in Section 12.2 shall prohibit the use of alternative procedures for the design of individual structures that demonstrate acceptable performance in accordance with the requirements of Section 1.4.1.3.
- 12.2.1.6 Alternative Structural Systems
- 12.2.1.7 Elements of Seismic Force-Resisting Systems