12.14.2 Design Principles
SBC 301 · Edition 2024 · p. 85
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 12.14.2.1 The structure shall include complete lateral force- and vertical force-resisting systems with adequate strength to resist the design seismic forces, specified in (Section 12.14.2), in combination with other loads.
- 12.14.2.2 The design seismic forces shall be distributed to the various elements of the structure and their connections using a linear elastic analysis in accordance with the procedures in Section 12.14.8.
- 12.14.2.3 The elements of the seismic force-resisting system and their connections shall be detailed to conform to the applicable requirements of the selected structural system set forth in Section 12.14.4.1.
- 12.14.2.4 Continuous load paths with sufficient strength and stiffness shall be provided to transfer all forces from the point of application to the final point of resistance.
- 12.14.2.5 Foundations shall be designed to accommodate the resulting forces.