11.9.2 Vertical Response Spectrum (M_CER)
SBC 301 · Edition 2024 · p. 65
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 11.9.2.1 Where a vertical response spectrum is required by (SBC 301) and site-specific procedures are not used, the vertical response acceleration shall be developed as given in (Section 11.9.2.1).
- 11.9.2.2 (SaMv) shall not be less than one-half of (SaM) corresponding to the horizontal components determined in accordance with the general or site-specific procedures in (Section 11.4 or Chapter 21).
- 11.9.2.3 For vertical periods greater than 2.0 s, (SaMv) shall be developed in accordance with the requirements of (Section 11.9.2.3).
- 11.9.2.4 As an alternative to using the procedure in Section 11.9.2.3, a site-specific study is permitted to be performed to obtain SaMv in accordance with the requirements of Section 11.9.2.4.