722.2.3.2 Reinforced beam cover.
SBC 201 · Edition 2024 · p. 219
The minimum thickness of concrete cover to the positive moment reinforcement (bottom steel) for reinforced concrete beams is shown in Table 722.2.3(3) for fire-resistance ratings of 1 hour to 4 hours.