710.1 Drainage
SBC 1101 · Edition 2024 · p. 259
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 710.1.1 Drains shall be provided around concrete foundations that are retained in the ground and that enclose habitable or usable spaces below grade.
- 710.1.2 Drain tile, gravel, crushed stone, perforated pipe, or other approved systems or materials shall be installed above or below the area to be protected and shall be discharged by gravity or by mechanical means into the drainage system.
- 710.1.3 The drain shall extend beyond the outside edge of the footing, its bottom elevation shall not be higher than the bottom of the base under the floor, and its top elevation shall not be less than 150 mm above the top of the footing. The top of the drain shall be covered with an approved filter membrane material.
- 710.1.4 Drainage slabs or perforated pipe shall be placed at least 50 mm from washed gravel or crushed rock of a size no less than one sieve size larger than the tile opening or hole, and covered with no less than 150 mm of the same material.