709.1 General
SBC 1101 · Edition 2024 · p. 257
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 709.1.1 A mat foundation shall be checked where the area of the isolated footings exceeds one-half of the plan area of the building foundation.
- 709.1.2 Definition of Load and Mat Foundation Area
- 709.1.3 Verification of Allowable Bearing Capacity
- 709.1.4 The bearing pressure distribution under mat foundations shall be consistent with the properties of the soil or rock and the structure, and with established principles of soil or rock mechanics.
- 709.1.5 Design Procedures
- 709.1.6 Flexure in mat foundations shall conform to the requirements of Section 4B5.
- 709.1.7 Reinforcement ratios in mat foundations shall comply with the requirements of (Section 707.10).
- 709.1.8 One-way shear and two-way shear in mat foundations shall conform to the requirements of Section 4B7 and Section 4B8, respectively.
- 709.1.9 Reinforcement anchorage shall conform to the requirements of Section 7A5.
- 709.1.10 Factored forces and factored moments at the base of columns shall be transferred to the foundations by concrete and reinforcement dowels, in accordance with the requirements of (Section 707.11.6).
- 709.1.11 The direct design method given in (SBC 304) shall not be used for the design of a mat foundation.
- 709.1.12 In computing (dc), the distance from the extreme tension fiber to the center of the tension reinforcement, the concrete cover, the diameters of the reinforcing bars, and the perpendicular reinforcement under the reinforcement considered shall all be taken into account.