708.1 General
SBC 1101 · Edition 2024 · p. 256
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 708.1.1 The shape of the footing shall be selected such that the centroid of the soil-contact area coincides with the resultant of the loads of the column supported by the footing.
- 708.1.2 The distance from the exterior edge to the center of the resultant of the loads shall be equal to half the length of the footing, in order to obtain a rectangular combined footing.
- 708.1.3 The distribution of bearing pressure under combined footings shall be consistent with the properties of the soil and rock and the structure, and with the basic principles of soil or rock mechanics.
- 708.1.4 The net factored soil reaction (qun) shall be calculated by dividing the sum of the factored axial loads (Pub) by the footing area.
- 708.1.5 The bending moments and shear forces in combined footings shall be calculated by the principles of statics.
- 708.1.6 The transverse strips beneath each column shall be assumed to transfer the load from the longitudinal beam strips to the column.
- 708.1.7 Bending in combined footings shall conform to the requirements of Section 4B5.
- 708.1.8 The minimum reinforcement in combined footings shall be in accordance with the requirements of Section 707.10.
- 708.1.9 One-way shear in combined footings shall conform to the requirements of Section 4B7, and two-way shear shall conform to the requirements of Section 4B8.
- 708.1.10 Reinforcement anchorage shall conform to the requirements of Section 7A5.