707.8 Two-Way Shear
SBC 1101 · Edition 2024 · p. 253
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 707.8.1 For design purposes, the critical shear perimeter shall be defined at a distance (d/2) from the face of the column, and for an interior column it is given in accordance with the requirements of (Section 707.8.1).
- 707.8.2 The maximum required shear strength for a strip 1 m wide in an isolated footing at the face of the column, wall, or pedestal shall be computed following the soil pressure distribution in accordance with the requirements of (Section 707.8.2).
- 707.8.3 For two-way reinforced concrete members, the shear strength (Vc) shall be the least of the values calculated in accordance with the requirements of (Section 707.8.3).
- 707.8.4 The value of (αs) for interior columns, edge columns and corner columns shall be determined in accordance with the requirements of (Section 707.8.4).