707.6 Required Flexural Strength
SBC 1101 · Edition 2024 · p. 252
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 707.6.1 Critical Sections for Shallow Foundations
- 707.6.2 Circular or regular polygon-shaped concrete columns or piers are permitted to be treated as square members of equivalent area when determining the critical elements for moments, shear and reinforcement.
- 707.6.3 Analytical Modeling: The footing shall be modeled as a cantilever beam with a fixed restraint at the face of the column or wall in accordance with the requirements of Section 707.6.3.
- 707.6.4 The maximum required moment strength for a 1 m wide strip in an isolated footing shall be calculated at the face of the column, wall, or pedestals, following the soil pressure distribution in accordance with the requirements of (Section 707.6.4).
- 707.6.5 The required moment strength (Mu) at any section of the footing shall be the cantilever moment of the factored net soil pressure (qun). It shall be applied over the entire footing area on one side of the vertical plane in accordance with the requirements of (Section 707.6.5).