707.3 Footing area estimated based on the unfactored axial load
SBC 1101 · Edition 2024 · p. 250
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 707.3.1 The minimum footing area of the foundation shall be calculated from the unfactored forces and moments transmitted by the foundation to the soil or rock and the allowable bearing pressure (qa), selected through the principles of soil mechanics or rock mechanics.
- 707.3.2 The minimum footing area (Af) shall be determined as the maximum area obtained in accordance with the requirements of Section 707.3.2.