608.3.2 The minimum number of longitudinal reinforcing bars for reinforced concrete columns shall be as follows:

SBC 1101 · Edition 2024 · p. 222

(a) 3; enclosed by triangular ties. (b) 4; enclosed by rectangular or circular ties. (c) 6; enclosed by spiral ties.

These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.

Read the full clause
SBC 1101 608.3.2: The minimum number of longitudinal reinforcing bars for reinforced concrete columns shall be as follows: | Emtithal