- 508.1.1 The concrete cover for the reinforcement shall be in conformance with the requirements of Section 4A7.1.
- 508.1.2 The development lengths of deformed bars shall be designed in accordance with the requirements of Section 7A5.
- 508.1.3 Splices of deformed bars shall be in accordance with the requirements of Section 7A6.
- 508.1.4 Adequate anchorage shall be provided for tension reinforcement where reinforcement stress is not directly proportional to moment, as in inclined, sloped, or stepped roofs, or where tension reinforcement is not parallel to the compression face.