503.1 Loads Covered
SBC 1101 · Edition 2024 · p. 185
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 503.1.1 The design loads for solid slabs supported on reinforced concrete beams or walls shall be in accordance with the requirements of Chapters 3(A) and 3(D).
- 503.1.2 Dead load and live load.
- 503.1.3 Where the slab is part of the roof system, the roof live load and rain load shall be included in (Chapter 3(D)), as applicable.
- 503.1.4 Partition loads. Masonry partitions with a line load less than or equal to 6 kN per meter are permitted to be replaced by an equivalent uniform load in accordance with the requirements of Chapter 3(D).
- 503.1.5 Factored design load. The factored design load (wu) shall be the greatest value determined from the combination of dead load and live load using the load factors and load combinations given in (Chapter 3(A)).
- 503.1.6 Load effects of concentrated loads and openings shall be considered in the design.