4C4 Distribution of Flexural Reinforcement in Beams and One-Way Slabs
SBC 1101 · Edition 2024 · p. 183
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 4C4.1 Reinforcement shall be distributed to control cracking due to flexure in the tension zones of slabs and reinforced concrete beams provided with reinforcement for flexural strength in one direction only.
- 4C4.2 The spacing of reinforcing bars closest to the tension face shall not exceed the limits given in (Section 4C4.2).
- 4C4.3 Reduction of the Number and Width of Flexural Cracks
- 4C4.4 Where flanges of (T)-shaped beams are in tension, part of the tension reinforcement shall be distributed over the effective flange width as defined in accordance with the requirements of (Section 405.2), provided that the width does not exceed (ln/10) as shown in (Section 4C4.4). Where the effective flange width exceeds the value (ln/1
- 4C4.5