410.2 Modeling of Structural Elements and Systems
SBC 1101 · Edition 2024 · p. 159
These are the clause's opening lines. The full clause, with its tables and exceptions, opens in the code reader.
Read the full clauseUnder this clause
- 410.2.1 Moments at the floor or roof level shall be resisted by distributing the moment between the columns immediately above and below the floor under consideration in proportion to the relative column stiffness and considering the conditions of restraint.
- 410.2.2 For frames or continuous construction, consideration shall be given to the effect of load patterns on floors and roof on the transfer of moment to exterior and interior columns, and of eccentric loading due to other causes.
- 410.2.3 Simplification of the analysis model is permitted by assumption (a) or (b) or both: