3C13.5 Roof Overhangs
SBC 1101 · Edition 2024 · p. 144
The positive external wind pressure on the bottom surface of windward roof overhangs shall be determined using (Cp = 0.8) in combination with the pressure on the top surface determined in accordance with the requirements of (Section 3C13.5).